CBFGK - BUTACENE 800 RESIN, S01116

  • MSDS: CBFGK
  • Manufacturer: ELF ATOCHEM
  • Product Name: BUTACENE 800 RESIN, S01116
  • National Stock Number: 8040-00N067022
Product Identification

Product ID:BUTACENE 800 RESIN, S01116
MSDS Date:09/19/1991
FSC:8040
NIIN:00N067022
MSDS Number: CBFGK

Responsible Party
ELF ATOCHEM
THREE PARKWAY
PHILADELPHIA, PA 19102
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 800-328-2811

Cage: IO927

Contractor
ELF ATOCHEM NORTH AMERICA INC
PHILADELPHIA, PA 19103-3222 US

Telephone: 800-245-5858

Cage: 86460

Ingredients

HYDROXY COMPOUNDS; (FERROCENE GRAFTED HYDROXY TERMINATED

Fraction By Weight: 99%

OSHA PEL N/K

ACGIH TLV: N/K


P-CRESOL, 2,6-DI-TERT-BUTYL-; (2,6-DI-TERT-BUTYL-P-CRESOL)

CAS: 128-37-0

RTECS: GO7875000

Fraction By Weight: 100%

OSHA PEL 10 MG/M3

ACGIH TLV: 10 MG/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:DIRECT CONTACT OR VAPORS MAY
CAUSE SLIGHT IRRITATION. SKIN:LIQUID MAY CAUSE SLIGHT IRRITATION.
CHRONIC:NO EFFECTS FROM CHRONIC EXPOSURE ARE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:AS WITH OTHER ORGANIC SOLVENTS,
EXPOSURE MAY AGGRAVATE PRE-EXISTING CONDITIONS SUCH AS COLDS,
ALLERGIES, ASTHMA, EMPHYSEMA, PSORIASIS AND LOW BLOOD PRESSURE.

First Aid

First Aid:EYES:IMMED FLUSH W/FLOWING WATER FOR @ LEAST 15 MINS. SEE
PHYS IF IRRIT PERSISTS. SKIN:REMOVE CONTAMD CLTHG & WASH EXPOS SKIN
W/LG AMTS OF WATER. SEE PHYS IF IRRIT PERSISTS. INGEST:SEE PHYS IF
IRRIT P ERSISTS. INHAL:IF A PROBLEM DEVELOPS, REMOVE PERSON TO
FRESH AIR AND SUPPLY OXYGEN IF NECESSARY.

Fire Fighting

Flash Point Method:CC
Flash Point:>220F,>104C
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, FOAM, OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:SM QTYS OF BUTADIENE, ALONG W/OXIDES OF
CARBON. MOVE CNTNR FROM FIRE AREA IF POSS. COOL FIRE EXPOS CNTNRS
W/WATER WELL AFTER FIRE IS OUT TO PVNT POSS (SUPDAT)

Accidental Release

Spill Release Procedures:VENTILATE THE AREA AND REMOVE ALL IGNIT
SOURCES. CONTAIN SPILL BY BUILDING A DIKE USING ABSORB MATL.
COLLECT THE REMAINDER OF SPILL W/ABSORB MATL AND PLACE MATL INTO A
DRUM APPROVED FOR WASTE DISPOSAL .
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:MINIMIZE VAPORIZATION BY SEALING IN A
TIGHTLY CLOSED CONTAINER. STORE IN A COOL, WELL-VENTILATED AREA.
KEEP AWAY FROM HEAT, SPARKS & OPEN FLAMES.
Other Precautions:AVOID EYE AND SKIN CONTACT. WHEN TRANSFERRING FROM
CONTAINERS, GROUND AND BOND BOTH CONTAINERS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:PROVIDE LOC EXHAUST VENT WHERE HEAT CAN CAUSE POLYMER
BREAKDOWN, E.G. EXTRUSION, MOLDING & WHERE THERE IS A NEED(SUPDAT)
Protective Gloves:NITRILE OR NATURAL RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:IMPERVIOUS BODY COVERING & BOOTS WHERE
SPILLS/SPLASHING OCCUR. ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:EXPLOSIONS. HEAT FROM FIRE CAN GENERATE FLAM VAP THAT IS
HVR/AIR. VENT:TO DRAW DUSTS & FUMES FROM WORKER BRTHG ZONES. THE
FOLLOWING PUBLICATION OFFERS VENT GUIDELINES & TECHNIQUES:"INDUST
VE NT, A MANUAL OF REC PRACTICE." AVAIL FROM ACGIH.

Chemical Properties

Spec Gravity:1.0
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR BROWN ORANGE VISCOUS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS AND STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, OPEN FLAME, PROLONGED STORAGE AT
ELEVATED TEMPERATURES.
Hazardous Decomposition Products:OXIDES OF CARBON, BUTADIENE, IRON AND
SILICON COMPOUNDS.

Disposal

Waste Disposal Methods:DISPOSE OF SOLID WASTE AT PROPERLY PERMITTED
LANDFILLS OBSERVING ALL LOCAL, STATE AND FEDERAL REGS. CONTAMINATED
LIQUIDS SHOULD BE CONCENTRATED & INCINERATED @ PROPERLY PERMITTED
DISP SITE AGAIN OBSER VING ALL LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.